Skip to main navigation Skip to search Skip to main content

Hyperpolarization without persistent radicals for in vivo real-time metabolic imaging

  • Tim r. Eichhorn
  • , Yuhei Takado
  • , Najat Salameh
  • , Andrea Capozzi
  • , Tian Cheng
  • , Jean-Noël Hyacinthe
  • , Mor Mishkovsky
  • , Christophe Roussel
  • , Arnaud Comment* (Corresponding Author)
  • *Corresponding author for this work
  • École Polytechnique Fédérale de Lausanne
  • University of Lausanne
  • University of Geneva
  • Paul Scherrer Institute

Research output: Contribution to journal › Article › peer-review

Abstract

Hyperpolarized substrates prepared via dissolution dynamic nuclear polarization have been proposed as magnetic resonance imaging (MRI) agents for cancer or cardiac failure diagnosis and therapy monitoring through the detection of metabolic impairments in vivo. The use of potentially toxic persistent radicals to hyperpolarize substrates was hitherto required. We demonstrate that by shining UV light for an hour on a frozen pure endogenous substance, namely the glucose metabolic product pyruvic acid, it is possible to generate a concentration of photo-induced radicals that is large enough to highly enhance the 13C polarization of the substance via dynamic nuclear polarization. These radicals recombine upon dissolution and a solution composed of purely endogenous products is obtained for performing in vivo metabolic hyperpolarized 13C MRI with high spatial resolution. Our method opens the way to safe and straightforward preclinical and clinical applications of hyperpolarized MRI because the filtering procedure mandatory for clinical applications and the associated pharmacological tests necessary to prevent contamination are eliminated, concurrently allowing a decrease in the delay between preparation and injection of the imaging agents for improved in vivo sensitivity.
Original languageEnglish
Pages (from-to)18064-18069
Number of pages6
JournalPNAS
Volume110
Issue number45
DOIs
Publication statusPublished - 5 Nov 2013
Externally publishedYes

Bibliographical note

The authors thank Dr. J. J. van der Klink and Prof. R. Gruetter for initiating the DNP projects in Lausanne and for their support, and the Sample Environment and Polarised Targets group of the Paul Scherrer Institute for providing the polarizer cryostat and for granting access to the X-band ESR spectrometer. They also thank M. H. Lerche for providing the PA sample doped with OX063 trityl radicals for the microwave spectrum measurements. This work was supported by the Swiss National Science Foundation (Grants PP00P2_133562 and 200020_144424), the National Competence Center in Biomedical Imaging, the Centre d’Imagerie BioMédicale of the Université de Lausanne, Université de Genève, Hôpitaux Universitaires de Genève, Centre Hospitalier Universtaire Vaudois, Ecole Polytechnique Fédérale de Lausanne, and the Leenards and Jeantet Foundations.

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Fingerprint

Dive into the research topics of 'Hyperpolarization without persistent radicals for in vivo real-time metabolic imaging'. Together they form a unique fingerprint.

Cite this