Induction of labour at term with oral misoprostol versus a Foley catheter (PROBAAT-II): A multicentre randomised controlled non-inferiority trial

  • Mieke L.G. Ten Eikelder*
  • , Katrien Oude Rengerink
  • , Marta Jozwiak
  • , Jan W. De Leeuw
  • , Irene M. De Graaf
  • , Mariëlle G. Van Pampus
  • , Marloes Holswilder
  • , Martijn A. Oudijk
  • , Gert Jan Van Baaren
  • , Paula J.M. Pernet
  • , Caroline Bax
  • , Gijs A. Van Unnik
  • , Gratia Martens
  • , Martina Porath
  • , Huib Van Vliet
  • , Robbert J.P. Rijnders
  • , A. Hanneke Feitsma
  • , Frans J.M.E. Roumen
  • , Aren J. Van Loon
  • , Hans Versendaal
  • Martin J.N. Weinans, Mallory Woiski, Erik Van Beek, Brenda Hermsen, Ben Willem Mol, Kitty W.M. Bloemenkamp
*Corresponding author for this work
  • Leiden University
  • Academic Medical Centre
  • Ikazia Hospital
  • Onze Lieve Vrouwe Gasthuis
  • University Medical Center Groningen
  • Spaarne Gasthuis
  • Vrije Universiteit Amsterdam
  • Maxima Medical Centre
  • Catharina Hospital
  • Jeroen Bosch Ziekenhuis
  • Haga Ziekenhuis
  • Atrium Medisch Centrum
  • Martini Ziekenhuis
  • Gelderland Valley Hospital
  • University Medical Center, Radboud
  • St. Antonius Ziekenhuis
  • The Robinson Research Institute
  • University of Adelaide
  • South Australian Health And Medical Research Institute

Research output: Contribution to journal › Article › peer-review

Abstract

Background Labour is induced in 20-30% of all pregnancies. In women with an unfavourable cervix, both oral misoprostol and Foley catheter are equally effective compared with dinoprostone in establishing vaginal birth, but each has a better safety profile. We did a trial to directly compare oral misoprostol with Foley catheter alone. Methods We did an open-label randomised non-inferiority trial in 29 hospitals in the Netherlands. Women with a term singleton pregnancy in cephalic presentation, an unfavourable cervix, intact membranes, and without a previous caesarean section who were scheduled for induction of labour were randomly allocated to cervical ripening with 50 μg oral misoprostol once every 4 h or to a 30 mL transcervical Foley catheter. The primary outcome was a composite of asphyxia (pH ≤7·05 or 5-min Apgar score <7) or post-partum haemorrhage (≥1000 mL). The non-inferiority margin was 5%. The trial is registered with the Netherlands Trial Register, NTR3466. Findings Between July, 2012, and October, 2013, we randomly assigned 932 women to oral misoprostol and 927 women to Foley catheter. The composite primary outcome occurred in 113 (12·2%) of 924 participants in the misoprostol group versus 106 (11·5%) of 921 in the Foley catheter group (adjusted relative risk 1·06, 90% CI 0·86-1·31). Caesarean section occurred in 155 (16·8%) women versus 185 (20·1%; relative risk 0·84, 95% CI 0·69-1·02, p=0·067). 27 adverse events were reported in the misoprostol group versus 25 in the Foley catheter group. None were directly related to the study procedure. Interpretation In women with an unfavourable cervix at term, induction of labour with oral misoprostol and Foley catheter has similar safety and effectiveness.

Original languageEnglish
Pages (from-to)1619-1628
Number of pages10
JournalThe Lancet
Volume387
Issue number10028
Early online date3 Feb 2016
DOIs
Publication statusPublished - 16 Apr 2016

Funding

This study was partly funded by FondsNutsOhra , grant number 1102-065 . We thank all the women who participated in this trial, and all participating institutions and their staff for their contribution to this study, particularly the research nurses and midwives and other recruiting staff for their excellent work. Furthermore we acknowledge Annemarie van der Velden, Librarian at Groene Hart Ziekenhuis in Gouda, for helping with the literature search for the systematic review. Findings of this trial were presented at the 35th Annual Meeting of the Society of Maternal Fetal Medicine, San Diego, CA, USA, Feb 5, 2015.