Skip to main navigation Skip to search Skip to main content

Optimisation of topology, rating, control and insulation coordination of a large series–parallel DC windfarm

  • Ibrahim Ahmad Shehu* (Corresponding Author)
  • , Dragan Jovcic
  • , Peng Li
  • *Corresponding author for this work

Research output: Contribution to journal › Article › peer-review

8 Downloads (Pure)

Abstract

This study presents the design of a large DC series-parallel windfarm that considers the key operational challenges in determining the optimal generator equipment rating and DC transmission voltage control. With this topology, offshore platform is not needed, but wind speed dispersion over windfarms and generator outage possibilities demand generator DC output voltages beyond their ratings. An optimization algorithm is developed along with a complete cost model, which includes operational and capital costs with all topology options, in order to inform design decisions. The results are evaluated on a 100-generator, 25 ? 4, 1 GW, 525 kV test wind farm and performance is verified using detailed PSCAD/EMTDC time-domain simulation. The key finding is that a positive net present value (NPV) is achieved, avoiding power curtailment even under 3% generator outage, when an overvoltage coefficient of 1.145 pu is utilised on all wind generators, assuming use of a suitable DC transmission voltage control. Further, a wide-ranging parameter sensitivity analysis is performed, and tower arrangement for insulation requirements is proposed.
Original languageEnglish
Pages (from-to)200-212
Number of pages13
JournalIET, Renewable Power Generation
Volume18
Issue number2
Early online date21 Dec 2023
DOIs
Publication statusPublished - 3 Feb 2024

Bibliographical note

The authors are grateful for the financial support from the Nigerian Petroleum Technology Development Fund (PTDF).

Data Availability Statement

The data that support the findings of this study are available from the corresponding author upon reasonable request.

Funding

The authors are grateful for the financial support from the Nigerian Petroleum Technology Development Fund (PTDF). PTDF. Grant Number: PTDF/ED/OSS/PHD/SIA/1664/19

FundersFunder number
Nigerian Petroleum Development FundPTDF/ED/OSS/PHD/SIA/1664/19

    UN SDGs

    This output contributes to the following UN Sustainable Development Goals (SDGs)

    1. SDG 7 - Affordable and Clean Energy
      SDG 7 Affordable and Clean Energy

    Keywords

    • DC–DC power convertors
    • overvoltage
    • renewable energy power conversion
    • topology
    • wind farm design and operation
    • wind power

    Fingerprint

    Dive into the research topics of 'Optimisation of topology, rating, control and insulation coordination of a large series–parallel DC windfarm'. Together they form a unique fingerprint.