A novel electrochemical biosensor based on signal amplification of Au HFGNs/PnBA-MXene nanocomposite for the detection of miRNA-122 as a biomarker of breast cancer

Sara Ranjbari, Majid Rezayi* (Corresponding Author), Reza Arefinia* (Corresponding Author), Seyed Hamid Aghaee-Bakhtiari, Behnaz Hatamluyi, Alireza Pasdar

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

13 Citations (Scopus)

Abstract

Cancer is one of the leading causes of death worldwide and a crisis for global health. Breast cancer is the second most common cancer globally. In the perusal, a novel electrochemical biosensor amplified with hierarchical flower-like gold, poly (n-butyl acrylate), and MXene (AuHFGNs/PnBA-MXene) nanocomposite and activated by highly special antisense ssDNA (single-stranded DNA) provide a promising alternative for miRNA-122 detection as a biomarker of breast cancer. The biosensor presented a detection limit of 0.0035 aM (S/N = 3) with a linear range from 0.01 aM to 10 nM. The platform was tried on 20 breast cancer miRNAs extracted from actual serum specimens (10 positives and 10 negatives). Founded on the quantitatively obtained outcomes and statistic analysis (t-test, box-graph, receiver performance characteristic curve, and cut-off amount), the biosensor showed a meaningful discrepancy between the native and positive groups with 100% specificity and 100% sensitivity. While, RT-qPCR showed less specificity and sensitivity (70% specificity, 100% sensitivity) than the proposed biosensor. To assess the quantitative capacity and biosensor detection limit for clinical tests, the biosensor diagnosis performance for continually diluted miRNA extracted from patients was compared to that gained by RT-qPCR results, indicating that the biosensor detection limit was lower than RT-qPCR. ssDNA/AuHFGN/PnBA-MXene/GCE displayed little cross-reaction with other sequences and also showed desirable stability, reproducibility, and specificity and stayed stable until 32 days. As a result, the designed biosensor can perform as a hopeful method for diagnosis applications.

Original languageEnglish
Article number124247
JournalTalanta
Volume255
Early online date3 Jan 2023
DOIs
Publication statusPublished - 1 Apr 2023

Bibliographical note

Funding Information:
This study was financially supported by; 1) Ferdowsi University of Mashhad (Grant No. 55634 ), 2) The Deputy of Research, Mashhad University of Medical Sciences (Grant No. 991679 ), Mashhad, Iran.

Keywords

  • AuHFGN/PnBA-MXene
  • Breast cancer
  • Electrochemical biosensor
  • miRNA-122

Fingerprint

Dive into the research topics of 'A novel electrochemical biosensor based on signal amplification of Au HFGNs/PnBA-MXene nanocomposite for the detection of miRNA-122 as a biomarker of breast cancer'. Together they form a unique fingerprint.

Cite this