Novel non-targeted analysis of perfluorinated compounds using fluorine-specific detection regardless of their ionisability (HPLC-ICPMS/MS-ESI-MS)

Nor Laili Azua Jamari, Jan Frederik Dohmann, Andrea Raab, Eva M. Krupp, Joerg Feldmann* (Corresponding Author)

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

39 Citations (Scopus)
29 Downloads (Pure)

Abstract

Although perfluorooctanesulfonic acid (PFOS) and perfluorooctanoic acid (PFOA) have been phased out, there is a plethora of per- or polyfluoroalkyl substances (PFAS) generated and only a small number of these compounds are currently being monitored in environmental and biological sample using molecular mass spectrometry (MS). Total fluorine determination has revealed that a substantial amount of fluorinated organic compounds has not been identified. Due to the small mass deficiency of fluorine, it is not an easy task to screen successfully all fluorinated compounds including those which are not easy ionisable, hence a novel fluorine-specific detector is needed. Here, inductively-coupled plasma mass spectrometry (ICPMS) was used for the first time for the detection of PFAS, by using the novel approach to transfer F- into a detectable [BaF]+ in the argon plasma. A reverse phase-high performance liquid chromatography (RP-HPLC) method was developed and then online coupled to ICPMS/MS for the fluorine-specific detection and simultaneously to electrospray MS (ESI-MS) to separate perfluorinated carboxylic acids (PFCA) and perfluorooctanesulfonic acid (PFOS). The calibration was linear and was element-specific with detection limits of 0.49 mg F L-1 under gradient elution method. As a proof of concept, PFCA standards in methanol were not fully neutralised to force the esterification and those solutions were measured using HPLC-ICPMS/MS-ESI-MS. The methyl esters were not detectable by ESI-MS but by ICPMS/MS. This illustrates that the undetectable fluorine-containing compounds were detected and quantified by the element-specific detection of ICPMS/MS. The analysis of spiked river water at a sub-ppb level gave acceptable recovery using a SPE-based preconcentration method. Since ICPMS/MS method is element-specific detection, all non-fluorinated compounds interfering in ESI-MS were eliminated. Hence, HPLC-ICPMS/MS can be used as a non-targeted method of fluorinated compounds which may help the identification of novel fluorinated compounds in environmental and biological samples and helps with mining the ESI-MS data.
Original languageEnglish
Pages (from-to)22-31
Number of pages10
JournalAnalytica Chimica Acta
Volume1053
Early online date20 Nov 2018
DOIs
Publication statusPublished - 11 Apr 2019

Bibliographical note

NLAJ thanks the Malaysian Government (Grant number: RG12824-10) and the National Defence University of Malaysia for financial support throughout the study period, while JFD thanks the Erasmus program of the EU. Special thanks to the Swedish Research Council (Grant number: FORMAS 1397306) for additional financial support in this project.

Keywords

  • non-target method
  • ICPMS/MS
  • polyatomic ion [BaF]+
  • perfluoroalkyl substances
  • Polyatomic ion [BaF]
  • Perfluoroalkyl substances
  • Non-target method
  • Polyatomic ion [BaF] +
  • Polyatomic ion [BaF](+)
  • CHROMATOGRAPHY
  • WATER

Fingerprint

Dive into the research topics of 'Novel non-targeted analysis of perfluorinated compounds using fluorine-specific detection regardless of their ionisability (HPLC-ICPMS/MS-ESI-MS)'. Together they form a unique fingerprint.

Cite this