Preference, satisfaction and critical errors with Genuair and Breezhaler inhalers in patients with COPD: a randomised, cross-over, multicentre study

Sergi Pascual, Jan Feimer, Anthony De Soyza, Jaume Sauleda Roig, John Haughney, Laura Padullés, Beatriz Seoane, Ludmyla Rekeda, Anna Ribera, Henry Chrystyn, John Andrew Francis Haughney

Research output: Contribution to journalArticlepeer-review

31 Citations (Scopus)
8 Downloads (Pure)

Abstract

BACKGROUND: The specific attributes of inhaler devices can influence patient use, satisfaction and treatment compliance, and may ultimately impact on clinical outcomes in patients with chronic obstructive pulmonary disease (COPD).

AIMS: To assess patient preference, satisfaction and critical inhaler technique errors with Genuair (a multidose inhaler) and Breezhaler (a single-dose inhaler) after 2 weeks of daily use.

METHODS: Patients with COPD and moderate to severe airflow obstruction were randomised in a cross-over, open-label, multicentre study to consecutive once-daily inhalations of placebo via Genuair and Breezhaler, in addition to current COPD medication. The primary end point was the proportion of patients who preferred Genuair versus Breezhaler after 2 weeks (Patient Satisfaction and Preference Questionnaire). Other end points included overall satisfaction and correct use of the inhalers after 2 weeks, and willingness to continue with each device.

RESULTS: Of the 128 patients enrolled, 127 were included in the safety population (male n=91; mean age 67.6 years). Of the 110 of the 123 patients in the intent-to-treat population who indicated an inhaler preference, statistically significantly more patients preferred Genuair than Breezhaler (72.7 vs. 27.3%; P<0.001). Mean overall satisfaction scores were also greater for Genuair than for Breezhaler (5.9 vs. 5.3, respectively; P<0.001). After 2 weeks, there was no statistically significant difference in the number of patients who made ⩾1 critical inhaler technique error with Breezhaler than with Genuair (7.3 vs. 3.3%, respectively).

CONCLUSIONS: Patient overall preference and satisfaction was significantly higher with Genuair compared with Breezhaler. The proportion of patients making critical inhaler technique errors was low with Genuair and Breezhaler.

Original languageEnglish
Article number15018
Number of pages7
Journalnpj Primary Care Respiratory Medicine
Volume25
Early online date30 Apr 2015
DOIs
Publication statusPublished - 2015

Bibliographical note

The study was funded by Almirall S.A., Barcelona, Spain, and Forest Laboratories LLC, a subsidiary of Actavis PLC, New York, USA. Medical writing support was funded by Almirall S.A., Barcelona, Spain.

Keywords

  • Aged
  • Cross-Over Studies
  • Equipment Design
  • Equipment Failure
  • Female
  • Humans
  • Male
  • Middle Aged
  • Nebulizers and Vaporizers
  • Patient Satisfaction
  • Pulmonary Disease, Chronic Obstructive
  • Respiratory System Agents

Fingerprint

Dive into the research topics of 'Preference, satisfaction and critical errors with Genuair and Breezhaler inhalers in patients with COPD: a randomised, cross-over, multicentre study'. Together they form a unique fingerprint.

Cite this